High pressure multistage water pump
Type D/DG boiler feed water pump can deliver water without solid particle or the liquid which the chemical
and physical feature are similar with water and tempreture less than 140℃, the water pump is suitable for delivering water in mine, boiler feed water, heat water and urban water project etc.

Model Meaning Of High pressure multistage boiler feed water pump
DG 450 – 60 x 4
DG-- Bolier feed water pump
450-- Rated flow 450 m3/h
60-- The single stage head is 60 m
4--Stage
Boiler Feed Water Pump Performance Data |
Model |
Capacity |
Head
m |
Speed
r/min |
Motor Power
(Kw) |
Impeller Dia
mm |
Weight
kg |
m3/h |
L/S |
D6-50x2 |
6.3 |
1.75 |
100 |
2950 |
11 |
198 |
140 |
D6-50x12 |
6.3 |
1.75 |
600 |
2950 |
55 |
198 |
340 |
D25-50x3 |
25 |
6.94 |
150 |
2950 |
30 |
196 |
220 |
D25-50x12 |
25 |
6.94 |
600 |
2950 |
110 |
196 |
409 |
D46-50x12 |
46 |
12.78 |
600 |
2950 |
160 |
210 |
475 |
D85-67x9 |
85 |
23.6 |
603 |
2950 |
250 |
235 |
1840 |
D120-50x2 |
120 |
33.3 |
100 |
2950 |
55 |
213 |
640 |
D120-50x9 |
120 |
33.3 |
450 |
2950 |
220 |
213 |
1200 |
D155-67x9 |
155 |
43.1 |
603 |
2950 |
450 |
235 |
1800 |
D360-40X10 |
360 |
100 |
400 |
1480 |
630 |
360 |
2550 |
D580-70X10 |
580 |
161.1 |
700 |
1480 |
1800 |
473 |
4120 |
D720-60x9 |
720 |
200 |
540 |
1480 |
1600 |
450 |
3900 |
Pump testing